Manocon Bunker With Generator

Precast Bunker With Generator Room

The bunker with a generator room was developed for a site where a generator must be on site permanently with protection.  The first room is for the communication equipment and the second room for the housing and protection of the generator.  Each room has a separate concrete and steel door with a Bluetooth lock that only allows access to that specific room. This will enable the control room to give access to only one of the rooms as required while the other room stay locked.  To get access to the bunker, the person at the bunker must contact the control room and request an access code.  When the control room is satisfied that the person may enter,  they will in turn send back an access code to that person’s phone.  This code must then be entered into the Bluelock App (That can be downloaded from Playstore on any cell phone) which will open the door lock.  The access code will only be active for the time as requested from the control room.  The control room will receive confirmation from the Bluetooth lock when the door is closed and locked on completion.  When maintenance must be done to the generator or the diesel tank of the generator must be filled, the control room can give access to the generator room only while the equipment room stay locked.  When access is needed to the equipment room, the generator room can stay locked.  The dimensions of the door to the generator room is 1,4m wide x 2,24m high to allow installation of a generator.  The door opening to the equipment room is 1,1m wide x 2,24m high.  The generator room have galvanised steel louvres for ventilation as per the clients requirements.  The equipment room have a passive ventilation system installed for temperature control.

Bunker Specifications

Solid 50MPa Concrete & Steel Structure

The walls and roof sections of all the bunkers are manufactured from 50 MPa reinforced precast concrete panels that bolted together from the inside of the bunker when erected.

Top Class Security

Each door is fiited with a bluetooth lock that can only be opened remotely from the owners control rooms via access codes sent to onsite staff electronic cellular device.

Vibration Sensors

An additional security feature which is optional could be integrated with control rooms and NOC’s for early warning of any tampering at the bunker.

Temperature Controlled

The Manocon Precast Bunkers have an MTN approved passive cooling system.  Thus no extra cooling measures need to be taken to safe keep electronics.

Smaller Footprint

The Bunkers have a smaller footprint than the conventional installations with a reduced rental area.  The result is a huge saving in rent paid over a long period of time.

Galvanised Steel

All steel members used in the manufacturing of a Manocon Precast Concrete Bunker are Hot Dip Galvanised.